EMC D-SNC-DY-00최신인증시험기출자료 - D-SNC-DY-00퍼펙트덤프문제

EMC D-SNC-DY-00최신인증시험기출자료 - D-SNC-DY-00퍼펙트덤프문제

EMC D-SNC-DY-00최신인증시험기출자료 - D-SNC-DY-00퍼펙트덤프문제

Blog Article

Tags: D-SNC-DY-00최신 인증시험 기출자료, D-SNC-DY-00퍼펙트 덤프문제, D-SNC-DY-00완벽한 시험자료, D-SNC-DY-00인증시험 덤프공부, D-SNC-DY-00높은 통과율 인기 시험자료

EMC인증 D-SNC-DY-00시험은 인기있는 IT자격증을 취득하는데 필요한 국제적으로 인정받는 시험과목입니다. EMC인증 D-SNC-DY-00시험을 패스하려면 ITDumpsKR의EMC인증 D-SNC-DY-00덤프로 시험준비공부를 하는게 제일 좋은 방법입니다. ITDumpsKR덤프는 IT전문가들이 최선을 다해 연구해낸 멋진 작품입니다. EMC인증 D-SNC-DY-00덤프구매후 업데이트될시 업데이트버전을 무료서비스료 제공해드립니다.

EMC D-SNC-DY-00 시험요강:

주제소개
주제 1
  • SONiC Configuration: This comprehensive topic evaluates your ability to administer and configure critical network components. You will need to manage port groups, configure management access, handle VLANs, and verify advanced features like Link Aggregation Groups and MC-LAG. Proficiency in these Dell EMC D-SNC-DY-00 exam areas is crucial for ensuring robust and scalable network operations.
주제 2
  • SONiC Installation: Your proficiency in SONiC installation, upgrade, and downgrade methods will be tested in this Dell EMC D-SNC-DY-00 exam topic. You will need to install SONiC using both the ONIE manual and automatic methods. This topic measures your hands-on skills in managing SONiC installations efficiently.
주제 3
  • Routing: Here, your routing knowledge will be tested, particularly in administering L3 IP addressing, configuring static routes, and understanding OSPF and BGP operations. As a cloud engineer, you must be adept at managing routing protocols and configurations to maintain efficient network traffic flow.
주제 4
  • QoS: Your understanding of Quality of Service (QoS) is essential to become a certified Dell cloud engineer. The exam evaluates your ability to configure and verify QoS features. This section tests your ability to ensure optimal network performance, a vital skill in managing cloud environments where service quality is paramount.
주제 5
  • VXLAN: This topic focuses on your ability to manage VXLAN operations, including configuring and verifying BGP EVPN with both Asymmetric and Symmetric IRB. Understanding VXLAN is essential for enabling scalable and efficient cloud networks, making this topic critical to your D-SNC-DY-00 exam success.

>> EMC D-SNC-DY-00최신 인증시험 기출자료 <<

D-SNC-DY-00퍼펙트 덤프문제 & D-SNC-DY-00완벽한 시험자료

ITDumpsKR의 EMC인증 D-SNC-DY-00덤프로 시험공부를 하신다면 고객님의 시간은 물론이고 거금을 들여 학원등록하지 않아도 되기에 금전상에서도 많은 절약을 해드리게 됩니다. EMC인증 D-SNC-DY-00덤프 구매의향이 있으시면 무료샘플을 우선 체험해보세요.

최신 Dell Networking D-SNC-DY-00 무료샘플문제 (Q31-Q36):

질문 # 31
What is the correct order of steps for data flow in asymmetric IRB frame encapsulation?

정답:

설명:

Explanation:
* Ingress VTEP performs a route lookup that is based on the destination IP address.
* Ingress VTEP encapsulates the packet with VXLAN and sends it on the appropriate VNI segment.
* Egress VTEP determines that the host is local to the VNI and switches the packet.
* Egress VTEP bridges the packet after decapsulation.
Steps and Correct Order:
* Ingress VTEP performs a route lookup that is based on the destination IP address.
* The ingress VTEP (Virtual Tunnel Endpoint) first needs to determine the next hop for the packet.
This involves performing a route lookup using the destination IP address.
* Ingress VTEP encapsulates the packet with VXLAN and sends it on the appropriate VNI segment.
* Once the route lookup is complete, the ingress VTEP encapsulates the packet in a VXLAN header, which includes the appropriate VNI (VXLAN Network Identifier) segment, and forwards it.
* Egress VTEP determines that the host is local to the VNI and switches the packet.
* The egress VTEP receives the encapsulated VXLAN packet, decapsulates it, and then checks its local VNI to determine if the destination host is within the same VNI.
* Egress VTEP bridges the packet after decapsulation.
* After determining the destination host's locality, the egress VTEP bridges the packet to the appropriate interface to deliver it to the final destination.
References:
* Dell Technologies Networking - SONiC
* Dell Enterprise SONiC Deployment Guide
These steps provide a comprehensive guide to understand the correct order of operations in asymmetric IRB (Integrated Routing and Bridging) frame encapsulation within a VXLAN environment.


질문 # 32
Use the simulator to perform the following configuration task.
1. Map a single-tagged CVLAN 100 to SVLAN 200 translation on PE
switch interface Eth1/1.
2. Map a double-tagged VLAN packet with an outer CVLAN 100 and an
inner dot1q 200 to SVLAN 300 translation on PE switch interface
Eth1/2.
The necessary VLANs and VLAN stacking have already been configured.

정답:

설명:
see the explanation for all step by step solution with all explanation.
Explanation:
Here are the steps to configure the required VLAN translations on a Dell SONiC switch:
* Map a Single-Tagged CVLAN 100 to SVLAN 200 on Interface Eth1/1:
sonic# configure terminal
sonic(config)# interface Ethernet1/1
sonic(config-if-Ethernet1/1)# switchport mode trunk
sonic(config-if-Ethernet1/1)# switchport vlan mapping 100 200
sonic(config-if-Ethernet1/1)# end
sonic# write memory
* Map a Double-Tagged VLAN Packet with Outer CVLAN 100 and Inner dot1q 200 to SVLAN 300 on Interface Eth1/2:
sonic# configure terminal
sonic(config)# interface Ethernet1/2
sonic(config-if-Ethernet1/2)# switchport mode trunk
sonic(config-if-Ethernet1/2)# switchport vlan mapping 100 200 300
sonic(config-if-Ethernet1/2)# end
sonic# write memory
Comprehensive Detailed Step by Step Explanation with References:
* Enter Configuration Mode:
* Access the global configuration mode using the configure terminal command.
* Configure Interface Eth1/1:
* Enter interface configuration mode for Ethernet1/1 using the command interface Ethernet1/1.
* Set the switchport mode to trunk with the command switchport mode trunk.
* Configure the VLAN translation using the switchport vlan mapping 100 200 command, which maps CVLAN 100 to SVLAN 200.
* Exit the interface configuration mode by typing end.
* Save the configuration with write memory.
* Configure Interface Eth1/2:
* Enter interface configuration mode for Ethernet1/2 using the command interface Ethernet1/2.
* Set the switchport mode to trunk with the command switchport mode trunk.
* Configure the double-tagged VLAN translation using the switchport vlan mapping 100 200 300 command, which maps packets with outer CVLAN 100 and inner dot1q 200 to SVLAN 300.
* Exit the interface configuration mode by typing end.
* Save the configuration with write memory.
References:
* Dell Technologies Networking - SONiC
* Dell Enterprise SONiC Deployment Guide
These steps provide a comprehensive guide to configure VLAN translations on a Dell SONiC switch, ensuring that the specific requirements for single-tagged and double-tagged VLAN mappings are met.


질문 # 33
What are three characteristics of VLAN translation?

  • A. By default, VLAN stacking is enabled on Z9432F-ON switches.
  • B. SVLAN configuration for both Q-in-Q VLAN tunneling and VLAN translation is possible on the same interface.
  • C. VLAN translation is not supported on MC-LAG port channel interfaces.
  • D. Trunk or access ports can be configured as members of any VLANs that are not used as an SVLAN.
  • E. The SVLAN header is replaced with a VNI if the provider network uses a VXLAN overlay.

정답:B,C,D

설명:
* VLAN translation is not supported on MC-LAG port channel interfaces (A): This is a restriction commonly seen in network configurations involving Multi-Chassis Link Aggregation (MC-LAG) where VLAN translation capabilities are not applied.
* Trunk or access ports can be configured as members of any VLANs that are not used as an SVLAN (B): This ensures that the VLAN configuration on trunk or access ports is flexible and does not overlap with Service VLANs (SVLANs).
* SVLAN configuration for both Q-in-Q VLAN tunneling and VLAN translation is possible on the same interface (E): This allows for complex VLAN tagging and translation configurations to be applied to the same interface, supporting advanced networking scenarios.
References:
* Dell Technologies SONiC documentation
* Dell Networking Configuration Guide


질문 # 34
Refer to the exhibit.

Which three actions can a customer take to change interface Eth1/10 to operate in access mode for VLAN 40?

  • A. Enter it into the relevant interface.
  • B. Shut down the relevant interface.
  • C. Remove the current access VLAN configuration.
  • D. Delete VLAN 40.
  • E. Configure the access mode for the switch port.

정답:A,C,E

설명:
* Configure the access mode for the switch port (A): This involves setting the switch port to operate in access mode.
* Remove the current access VLAN configuration (D): Before changing the VLAN, the current configuration must be cleared.
* Enter it into the relevant interface (E): Apply the new configuration to the specific interface, Eth1/10.
Steps:
* interface Ethernet 1/10
* no switchport access vlan <current VLAN> (Remove current VLAN)
* switchport mode access
* switchport access vlan 40
References:
* Dell Technologies SONiC documentation
* Dell Networking Configuration Guide


질문 # 35
Refer to the exhibit.

What is the primary VRRP router for VRRP group 10?

  • A. Router-3
  • B. Router-1
  • C. Router-2

정답:C

설명:
Based on the exhibit, Router-2 has the highest priority (90) in VRRP group 10. In VRRP, the router with the highest priority becomes the primary (master) router. Therefore, Router-2 is the primary VRRP router for VRRP group 10.
References:
* Dell Technologies SONiC VRRP Configuration Guide
* VRRP Protocol Overview


질문 # 36
......

ITDumpsKR 의 EMC인증 D-SNC-DY-00덤프는EMC인증 D-SNC-DY-00시험에 도전장을 던진 분들이 신뢰할수 있는 든든한 길잡이 입니다. EMC인증 D-SNC-DY-00시험대비 덤프뿐만아니라 다른 IT인증시험에 대비한 덤프자료도 적중율이 끝내줍니다. EMC인증 D-SNC-DY-00시험이나 다른 IT인증자격증시험이나ITDumpsKR제품을 사용해보세요.투자한 덤프비용보다 훨씬 큰 이득을 보실수 있을것입니다.

D-SNC-DY-00퍼펙트 덤프문제: https://www.itdumpskr.com/D-SNC-DY-00-exam.html

Report this page